Menu

Products / Single Compression Heavy Duty Cable Glands

Technical Data
Material Brass (IS-319) Standard (Al. / S.S. / M.S. also available)
Plating Nickle Plated Standard (Chrome also available)
Entry Threads Metric threads with 1.5 pitch as per IS 4218 standard
Sealing Rubber Ring Synthetic / Natural
Gland Standard IS 12943 : 1990
Ingress Protection IP 60 as per IS 12063
Application Single Compression Glands are weather proof and dust proof (IP-60) which can be used in normal climatic condition. Also when protected by PVC shrouds it can be used in corrosive atmosphere.

These glands are available in different sizes and are suitable for all cables upto 1000 sq. mm. and control cables upto 61 cores.
Designation Single Compression Glands are designated as below : SCGn, where
SC Single Compression
G Gland
n(n=1, 2,....20) Gland Size For eg.(SCG1, SCG2,...... SCG20)
Accessories PVC Shroud, Earth Tag, Stopping Plug, Reducer, Adaptor, etc. are available with specified dimensions in accordance to the Gland separately.
Fitting Sequence Pass the Compression Nut (Part-5), one Metal Washer (Part-3) & Outer Seal Ring (Part-4) in succession order over the outer sheath of the cable before commencing to strip the cable

Remove the outer sheath to the desired length depending on the length of the beds required.

Pass the 2nd Metal Washer (Part-3) over the exposed armour and then splay out the armour wire one by one. Now cut the armour wire according to the size of the metal washer and bend the same. Pass the 3rd Metal Washer (Part-3) over the inner sheath and place it over the bended armour, so that the armour wires are now secured between the two Metal Washer.

Push the assembly through the Gland Body (Part-2) and tighten the Compression Nut (Part-5). While doing so the outer seal ring will expand in radial direction and will grip the cable. This will ensure dust proof entry of the cable.

Finally apply the fitted gland assembly to the extreme with the entry thread provided, if the enclosure does not have threaded entry than tight the gland assembly with the Check Nut (Part-1).
Suitable Cable
Overall Dia
Size
Code
D1
Nipple Entry
Threads in Metrics
D2
Dia.
D3
Dia.
D4
(A/F)
D5
(A/C)
L1
Length
From To SCG mm Ø mm Ø mm mm mm mm
9.0 12.0 SCG 1 16 x 1.5 12.0 16.0 22.0 25.5 9.0
12.0 15.0 SCG 2 16 x 1.5 12.0 18.5 25.0 29.0 9.0
12.0 15.0 SCG 3 20 x 1.5 15.0 18.5 25.0 29.0 9.0
15.0 18.0 SCG 4 20 x 1.5 15.0 24.0 30.0 34.5 9.5
16.0 20.0 SCG 5 25 x 1.5 20.5 24.0 31.5 36.0 9.5
20.0 24.0 SCG 6 25 x 1.5 20.5 28.5 35.0 40.0 10.0
24.0 28.0 SCG 7 32 x 1.5 27.0 33.0 40.0 46.0 12.0
28.0 32.0 SCG 8 40 x 1.5 34.0 37.0 46.0 53.0 12.0
33.0 37.0 SCG 9 40 x 1.5 34.0 41.0 50.0 57.5 12.0
37.0 42.0 SCG 10 50 x 1.5 44.0 47.0 58.0 67.0 13.0
43.0 48.0 SCG 11 50 x 1.5 44.0 52.0 65.0 75.0 13.0
49.0 54.0 SCG 12 63 x 1.5 55.0 61.5 73.0 84.0 14.0
55.0 60.0 SCG 13 63 x 1.5 55.0 65.0 77.0 89.0 14.0
61.0 66.0 SCG 14 75 x 1.5 68.0 71.0 85.0 98.0 15.0
67.0 72.0 SCG 15 75 x 1.5 67.0 76.0 90.0 104.0 15.0
73.0 78.0 SCG 16 82 x 1.5 73.0 82.0 97.0 112.0 17.0
79.0 84.0 SCG 17 90 x 1.5 81.0 91.0 108.0 124.0 19.0
84.5 92.0 SCG 18 100 x 1.5 91.0 98.0 117.0 135.0 20.0
93.0 100.0 SCG 19 110 x 1.5 100.0 107.0 127.0 146.0 25.0
101.0 115.0 SCG 20 125 x 1.5 113.0 118.0 142.0 164.0 25.0
Home | About Us | Application | Quality / Our Vision | Process | Products | Selection Guide | Inquiry | Contact Us